DETECTOR HEAT PHOTO 4D

People detect danger by relating many observations to one another and comparing them to familiar patterns.The simultaneous use of multiple senses allow humans to filter out situations which are not dangerous. The ability to detect danger depends largely on intelligence and knowledge from past experience. Edwards 4D detectors provide both.

The SIGA-IPHS Intelligent 4D Multisensor Detector gathers analog information from each of its three fire sensing
elements (ionization; photoelectric; and heat) and converts it into digital signals.The detector?s on-board microprocessor measures and analyzes these signals separately with respect to a fourth element - Time. We call this technology 4D. It compares the information to historical readings; time patterns and several known fire characteristics to makean alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated.



Standard Features
?Integrates three sensing technologies
Processes and analyzes information from each sensor (ion/photo/heat) separately using dynamic
filters then applies a sophisticated algorithm for optimum detection accuracy.
?Non-volatile memory
Permanently stores serial number; type of device; and job number. Automatically updates historic information
including hours of operation; last maintenance date; number of alarms and troubles; time of last alarm1 and
analog signal patterns for each sensing element just before last alarm.
?Automatic device mapping
Each detector transmits wiring information regarding its location with respect to other devices on
the circuit. Detectors installed in the wrong location during cleaning are automatically reported to
the loop controller.
?Electronic addressing
Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded
from a PC;or the SIGA-PRO Signature Program/Service Tool.
?Environmental compensation
Each sensing element self-compensates for changes in the detector?s installed environment to
maintain the sensitivity setting and prevent unwanted alarms. The detector reports when it cannot
compensate any further.
?Integral microprocessor - Intelligent detector
All decisions are made at the detector allowing lower communication speed while substantially
improving control panel response time. Less sensitive to line noise and loop wiring properties;
twisted or shielded wire is not required
?Wide 0.67- 3.70%/ft. sensitivity range window
Program the detector to operate at any one of five sensitivity settings within the window.
?Pre-alarm
Detector stores one of 20 pre-alarm sensitivity values to alert local personnel prior to the sensor reaching
a full evacuation sensitivity. Sensitivity values can be set in 5% increments.


In stock
Only 41 left
SKU
ES-GSA-IPHS
Call for Price

Found this item at a lower price?

Click the icon below to request a price match

Follow our social media pages to stay informed about our offers and events

People detect danger by relating many observations to one another and comparing them to familiar patterns.The simultaneous use of multiple senses allow humans to filter out situations which are not dangerous. The ability to detect danger depends largely on intelligence and knowledge from past experience. Edwards 4D detectors provide both.

The SIGA-IPHS Intelligent 4D Multisensor Detector gathers analog information from each of its three fire sensing
elements (ionization; photoelectric; and heat) and converts it into digital signals.The detector?s on-board microprocessor measures and analyzes these signals separately with respect to a fourth element - Time. We call this technology 4D. It compares the information to historical readings; time patterns and several known fire characteristics to makean alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually eliminated.



Standard Features
?Integrates three sensing technologies
Processes and analyzes information from each sensor (ion/photo/heat) separately using dynamic
filters then applies a sophisticated algorithm for optimum detection accuracy.
?Non-volatile memory
Permanently stores serial number; type of device; and job number. Automatically updates historic information
including hours of operation; last maintenance date; number of alarms and troubles; time of last alarm1 and
analog signal patterns for each sensing element just before last alarm.
?Automatic device mapping
Each detector transmits wiring information regarding its location with respect to other devices on
the circuit. Detectors installed in the wrong location during cleaning are automatically reported to
the loop controller.
?Electronic addressing
Permanently stores programmable address; there are no switches or dials to set. Addresses are downloaded
from a PC;or the SIGA-PRO Signature Program/Service Tool.
?Environmental compensation
Each sensing element self-compensates for changes in the detector?s installed environment to
maintain the sensitivity setting and prevent unwanted alarms. The detector reports when it cannot
compensate any further.
?Integral microprocessor - Intelligent detector
All decisions are made at the detector allowing lower communication speed while substantially
improving control panel response time. Less sensitive to line noise and loop wiring properties;
twisted or shielded wire is not required
?Wide 0.67- 3.70%/ft. sensitivity range window
Program the detector to operate at any one of five sensitivity settings within the window.
?Pre-alarm
Detector stores one of 20 pre-alarm sensitivity values to alert local personnel prior to the sensor reaching
a full evacuation sensitivity. Sensitivity values can be set in 5% increments.


Info
SKU ES-GSA-IPHS
Weight 1.000000
Manufacturer EDWARDS
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account

Payment Plan:

The items you need are well within your reach. ShopSSLTT has the premium products you want at affordable prices and with our shop now pay later payment plans we make them accessible to all. Lear more on the following links

Payment plan Details : You can now finance your purchases with flexible payment planss clich here to learn how.

Requirements: Before you apply for the plan make sure you have all the required documents, click here to see the list of documents required.